OPSWORQ

Compliance · Lockout/tagout

A lockout/tagout program that holds up on the floor.

OSHA’s control of hazardous energy standard asks for more than locks. It asks for a program: procedures for each machine, trained people, and a yearly check that the procedures are actually followed.

Who it applies to

Who has to meet it.

Employers whose employees service or maintain machines or equipment where an unexpected start-up or release of stored energy could injure someone (29 CFR 1910.147). Normal production work is covered when a guard is removed or a body part goes into the danger zone.

What it requires

The parts, with the citation.

Lockout/tagout: what it requires
ElementWhat it takesCitation
Energy control programWritten procedures, employee training and periodic inspections, together1910.147(c)(1)
Machine proceduresWritten steps for shutting down, isolating, locking and verifying each piece of equipment. A narrow exception applies only when all of the standard’s conditions are met1910.147(c)(4)
Locks and tagsProvided by the employer, used only for energy control, standardized, durable and identifying who applied them1910.147(c)(5)
Periodic inspectionAt least once a year, by an authorized employee other than the ones using the procedure, and certified in writing1910.147(c)(6)
TrainingAuthorized, affected and other employees each trained to their role; retrained when jobs, equipment or procedures change1910.147(c)(7)
Outside contractors, group lockout and shift changesProcedures for each, so protection doesn’t lapse between people or companies1910.147(f)

How we build it in

Written, wired to the work, and kept true.

We list every machine and every energy source, write the procedure for each one with the people who maintain it, and photograph the isolation points so the procedure is clear at the machine.

The annual inspection goes on a calendar with an owner, the certification is kept, and a missed inspection shows up on a measure the same month, not at an OSHA visit.

Questions

Questions people ask.

Do we need a written procedure for every machine?

Generally yes. The standard allows an exception only when a specific list of conditions is all met, such as a single energy source that is readily identified and isolated. Most shops have machines that don’t qualify.

Who can do the annual inspection?

An authorized employee other than the ones using the procedure being inspected. It must be certified in writing.

Which requirements apply depends on your organization’s facts. Legal conclusions are confirmed with your counsel. Requirements checked 17 November 2026. General information, not legal advice.

Call Book a call (opens in a new tab)