OPSWORQ

Compliance · Emergency action plan

An emergency action plan people can actually follow.

When an OSHA standard requires an emergency action plan, it has to be in writing, kept at the workplace and available to employees. It also has to match the building and the people as they are today.

Who it applies to

Who has to meet it.

Employers covered by an OSHA standard that requires an emergency action plan, for example where employees are expected to evacuate rather than use portable fire extinguishers (29 CFR 1910.38). An employer with 10 or fewer employees may communicate the plan orally.

What it requires

The parts, with the citation.

Emergency action plan: what it requires
ElementWhat it takesCitation
ReportingHow a fire or other emergency is reported1910.38(c)(1)
EvacuationProcedures, the type of evacuation and the exit route assignments1910.38(c)(2)
Critical operationsProcedures for anyone who stays to run critical operations before they evacuate1910.38(c)(3)
Accounting for peopleHow everyone is accounted for after evacuation1910.38(c)(4)
Rescue and medical dutiesProcedures for employees who perform them1910.38(c)(5)
ContactsThe names or job titles of people to contact for more information1910.38(c)(6)
AlarmAn employee alarm system with a distinctive signal for each purpose1910.38(d)
Training and reviewDesignate and train people to assist; review the plan with each employee when it is written, when their responsibilities change and when the plan changes1910.38(e)–(f)

How we build it in

Written, wired to the work, and kept true.

We write the plan from a walk of the building, by job title rather than by name so it survives turnover, and post the parts people need where they will see them.

Reviews are triggered by the events the standard names: a new hire, a changed role, a moved room. Drills are scheduled and recorded, and the result of each drill feeds the next version of the plan.

Questions

Questions people ask.

Does a small office need a written plan?

If a standard requires a plan and you have more than 10 employees, it must be written. With 10 or fewer, it may be communicated orally, though most owners find a short written plan easier to keep consistent.

How often must we drill?

The emergency action plan standard requires review and training at set moments rather than a drill frequency. Other rules, your insurer or the fire marshal may set one, and drills are the best test of whether the plan works.

Which requirements apply depends on your organization’s facts. Legal conclusions are confirmed with your counsel. Requirements checked 17 November 2026. General information, not legal advice.

Call Book a call (opens in a new tab)